CM=SGL, ACU=ACC1, SARCR=CLK10, STM=PRS
Control
EN | CSEN Enable |
CMPPOL | CSEN Digital Comparator Polarity Select |
CM | CSEN Conversion Mode Select 0 (SGL): Single Channel Mode: One conversion of a single channel (when MCE = 0) or set of bonded channels (when MCE = 1) per conversion trigger. 1 (SCAN): Scan Mode: Scans multiple selected channels once per conversion trigger. 2 (CONTSGL): Continuous Single Channel: Continuous conversion of a single channel (when MCE = 0) or set of bonded channels (when MCE = 1). 3 (CONTSCAN): Continuous Scan Mode: Continuously scans multiple selected channels. |
SARCR | SAR Conversion Resolution. 0 (CLK10): Conversions last 10 internal CSEN clocks and are 10-bits in length. 1 (CLK12): Conversions last 12 internal CSEN clocks and are 12-bits in length. 2 (CLK14): Conversions last 14 internal CSEN clocks and are 14-bits in length. 3 (CLK16): Conversions last 16 internal CSEN clocks and are 16-bits in length. |
ACU | CSEN Accumulator Mode Select 0 (ACC1): Accumulate 1 sample. 1 (ACC2): Accumulate 2 sample. 2 (ACC4): Accumulate 4 sample. 3 (ACC8): Accumulate 8 sample. 4 (ACC16): Accumulate 16 sample. 5 (ACC32): Accumulate 32 sample. 6 (ACC64): Accumulate 64 sample. |
MCEN | CSEN Multiple Channel Enable |
STM | Start Trigger Select 0 (PRS): PRS Triggering. Conversions are triggered by the PRS channel selected in PRSSEL. 1 (TIMER): Timer Triggering. Conversions are triggered by a local CSEN timer reload. 2 (START): Software Triggering. Conversions are triggered by writing a 1 to the START field of the CMD register. |
CMPEN | CSEN Digital Comparator Enable |
DRSF | CSEN Disable Right-Shift |
DMAEN | CSEN DMA Enable Bit |
CONVSEL | CSEN Converter Select |
CHOPEN | CSEN Chop Enable |
AUTOGND | CSEN Automatic Ground Enable |
MXUC | CSEN Mux Disconnect |
EMACMPEN | Greater and Less Than Comparison Using the Exponential Moving Average (EMA) is Enabled |
WARMUPMODE | Select Warmup Mode for CSEN |
LOCALSENS | Local Sensing Enable |
CPACCURACY | Charge Pump Accuracy |